Connex
®
CSK software
Installation guide
Software version 4.1.X
CP 100™
an
d CP 200™
electrocardiographs
Spot Vital Signs
®
LXi™
vital signs device
CP 150™
electrocardiograph
VSM
®
6000 Series
vital signs device
CP 50™
electrocardiograph
Page view 0
1 2 3 4 5 6 ... 45 46

Summary of Contents

Page 1 - CSK software

Connex®CSK softwareInstallation guideSoftware version 4.1.XCP 100™and CP 200™electrocardiographsSpot Vital Signs®LXi™vital signs deviceCP 150™electroc

Page 2

6 Overview Welch Allyn Connex CSK softwareCP 50, CP 100, CP 150 and CP 200 configuration examplesStandalone configuration, removable media or USBClien

Page 3 - Contents

Installation guide Overview 7Network configuration, wireless or EthernetCardioPerfect Workstation (client)No connectivity software installedServerInst

Page 4

8 Overview Welch Allyn Connex CSK software

Page 5 - Overview

29InstallationSpot LXi and VSM 6000 SeriesBefore you install the Welch Allyn Connex CSK software do the following:• Verify that the connectivity setti

Page 6 - System requirements

10 Installation Welch Allyn Connex CSK software2. Select SPOT LXi or VSM6000. This screen appears:3. Select SPOT LXi or VSM6000. This screen appears:4

Page 7 - About Connex CSK software

Installation guide Installation 11To uninstall the Welch Allyn Connex CSK software1. Insert the Welch Allyn Connex CSK CD. This screen appears:2. Sele

Page 8 - Client-server configuration

12 Installation Welch Allyn Connex CSK softwareCP 50, CP 100, CP 150, or CP 200Before you install the Welch Allyn Connex CSK software do the following

Page 9 - Subnet #2

Installation guide Installation 13To install the Welch Allyn Connex CSK software1. Insert the Connex CSK CD. This screen appears:If this screen does n

Page 10

14 Installation Welch Allyn Connex CSK software3. Select CP50/100/150/200. This screen appears:4. Choose either Server or Client based on your configu

Page 11

315ConfigurationConfiguring the CP 50, CP 150, and CP 200 patient-match criteria(resolving patients)When a test is imported into the CardioPerfect dat

Page 12

ii Welch Allyn Connex CSK software© 2013 Welch Allyn. All rights are reserved. To support the intended use of the product described in this publicatio

Page 13 - Installation

16 Configuration Welch Allyn Connex CSK software3. Save the file.4. Restart the CPSAPI service. (Go to Control Panel > Administrative Tools >Ser

Page 14

Installation guide Configuration 17Configuring the CardioPerfect Workstation fornon-Welch Allyn devicesCardioPerfect Workstation uses the SCP-ECG plug

Page 15 - 3. Follow the prompts

18 Configuration Welch Allyn Connex CSK softwareTo configure the plug-in for automatic ECG importingThis procedure configures the CardioPerfect progra

Page 16

Installation guide Configuration 19Data Catcher configurationThe Data Catcher application acts as a gateway between devices and external informationho

Page 17

20 Configuration Welch Allyn Connex CSK softwareGeneral settings1 Start button Selecting this starts the device server portion of Data Catcher.2 Stop

Page 18

Installation guide Configuration 217 Local Failed DataCache file typesThis option allows you to specify what types of failed message data files should

Page 19 - Configuration

22 Configuration Welch Allyn Connex CSK softwareDevice network settings1 DevicetransmissiontimeoutThis value represents the maximum time, in seconds,

Page 20 - 3. Save the file

Installation guide Configuration 23Information network settings1 DatatransmissiontimeoutThis value represents the maximum time, in seconds, that a con

Page 21

24 Configuration Welch Allyn Connex CSK software5 Automatic hostresolutionIn certain system configurations, the IP address of the external host is eit

Page 22

Installation guide Configuration 2514 Host responseXSLTThe Host Response XSLT field is used to specify the location of an .xsl file that will be usedt

Page 23 - Data Catcher configuration

iiiContents1 - Overview ...1About this guide ...1General wa

Page 24 - General settings

26 Configuration Welch Allyn Connex CSK softwareUser interface settings1 Web port The port value that will host the Web interface for Data Catcher.Not

Page 25

Installation guide Configuration 27Data logsTo provide assistance in monitoring messages that are processed by Data Catcher,specifically ones that fai

Page 26 - Device network settings

28 Configuration Welch Allyn Connex CSK softwareAdding CVSM to a Connex CSK installationThe Connex VSM is only supported on CSK installations of versi

Page 27 - Information network settings

Installation guide Configuration 29Connecting Connex CSK to multiple device modelsIf you wish to connect multiple devices models to CSK, you will need

Page 28

30 Configuration Welch Allyn Connex CSK softwareFile Importer configurationFile Importer is a software program that allows you to transfer patient vit

Page 29

Installation guide Configuration 31Logs tabThe Logs tab allows you to read logged messages to either confirm a test was importedcorrectly or determine

Page 30 - User interface settings

32 Configuration Welch Allyn Connex CSK software

Page 31 - Debug logs

433TroubleshootingAbout the connectivity software modulesThe Connex CSK software comprises a set of modules that are installed separately asneeded. Th

Page 32

34 Troubleshooting Welch Allyn Connex CSK softwareFunctional diagramsSoftware modules in a standalone CardioPerfect Workstation, removable media or US

Page 33

Installation guide Troubleshooting 35Software modules in a client-server configuration, removable media or USBSoftware modules in a client-server netw

Page 34 - File Importer configuration

iv Contents Welch Allyn Connex CSK software

Page 35 - Import failures tab

36 Troubleshooting Welch Allyn Connex CSK softwareSoftware modules in a simple network configuration, wireless or EthernetSoftware modules in a USB co

Page 36

Installation guide Troubleshooting 37Reassigning a server IP addressWho needs this procedure?Users with a client-server configuration wired to the cli

Page 37 - Troubleshooting

38 Troubleshooting Welch Allyn Connex CSK softwareTroubleshooting chartConditions Causes Actions1. View AvailableNetworks screendoes not return anyava

Page 38 - Functional diagrams

Installation guide Troubleshooting 394. Test send (orpatient search) failed— wireless orethernet.No patient order found or patientsearch contained no

Page 39

40 Troubleshooting Welch Allyn Connex CSK software5. Test send(or search) failed —USB cable.Cables not connected. Make sure USB cable is connected on

Page 40

Installation guide Troubleshooting 417. Data Catcherconfiguration page isinaccessibleThe configuration web-interface hasbeen disabled1. Open DataCatch

Page 41

42 Troubleshooting Welch Allyn Connex CSK software

Page 42 - Troubleshooting chart

11OverviewAbout this guideThis guide describes how to install, configure, and troubleshoot the Welch Allyn ConnexCSK (Connectivity Solutions Kit) soft

Page 43

2 Overview Welch Allyn Connex CSK softwareSystem requirementsOperating systemsStandalone PCWindows XP SP2 (x86 and x64), Windows Vista Business SP1(x8

Page 44

Installation guide Overview 3About Connex CSK softwareThe Welch Allyn Connex CSK software is a collection of software modules that enablevarious Welch

Page 45

4 Overview Welch Allyn Connex CSK softwareSpot LXi and VSM 6000 Series configuration examplesClient-server network configuration, wireless or Ethernet

Page 46

Installation guide Overview 5Network configuration with multiple subnetsServerInstallation menu option:“Server”Subnet #1Workstation (client)Installati