KleenSpec
®
Illumination
Storage System
Model # 78820
Mounting Instructions
Choose the mounting method best suited to your mounting surface type:
KleenSpec
®
Illumination
Storage System
Model # 78820
Mounting Instructions
Choose the mounting method best suited to your mounting surface type:
Affixing the Storage System to wallboard:
Tools required: Phillips Screwdriver, Wall Anchors/Screws (provided), Hole
Template (provided on back)
1. Locate the desired wall location for the unit and verify there are no
wall studs behind the wallboard.
2. Placing the template vertically on the wall and using the screwdriver,
mark the hole location into the wall for both screws. Twist a wall
anchor into each hole location on the wall until fully seated. See
Figure 1.
3. Drive a mounting screw into each wall anchor until the screw head is
approximately 1/8” (3mm) from the wall. See Figures 2 and 3.
4. To mount the KleenSpec Illumination Storage System, fit the round key
holes in the back of the system over screw heads on the wall and push
down.
Affixing the Storage System to other surfaces:
Tools required: Alcohol Swab, Lint-Free Cloth, Double-Sided Tape (provided)
1. Locate the desired location for the storage system.
2. Using an alcohol swab, clean all surface mounting areas thoroughly
and then dry with a lint-free cloth.
3. Peel away the backing from one side of the two pieces of double-sided
tape and attach the two pieces of double-sided tape over each of the
key holes on the back of the KleenSpec Illumination Storage System.
See Figure 4.
4. Peel away the backing for the double-sided tape and firmly press the
KleenSpec Illumination Storage System to the cleaned surfaces. See
Figure 5. For best adhesion results, do not use the storage system for
24 hours.
Using the Storage System
1. Slide the card of replacement lamps (REF 08800 lamps purchased
separately) inside the storage system from the top. See figure on
reverse.
2. Plug the KleenSpec Illuminator into the outlet. If necessary, wrap the
excess transformer cord between the wall and the storage system.
Place the Vaginal Speculum Illuminator into the front opening of the
storage system.
To clean the KleenSpec Illumination Storage System, wipe it with 70%
Alcohol, CaviWipes, or 10% Bleach Solution.
NOTE: VERIFY LAMP IS TURNED OFF BEFORE PLACING IT INTO THE STORAGE SYSTEM.
Material No. 1200002
1/8” / 3 mm
Figure 1
Figure 2
4”
/
1
0cm
Figure 3
Figure 4
Figure 5
Affixing the Storage System to wallboard:
Tools required: Phillips Screwdriver, Wall Anchors/Screws (provided), Hole
Template (provided on back)
1. Locate the desired wall location for the unit and verify there are no
wall studs behind the wallboard.
2. Placing the template vertically on the wall and using the screwdriver,
mark the hole location into the wall for both screws. Twist a wall
anchor into each hole location on the wall until fully seated. See
Figure 1.
3. Drive a moutning screw into each wall anchor until the screw head is
approximately 1/8” (3mm) from the wall. See Figures 2 and 3.
4. To mount the KleenSpec Illumination Storage System, fit the round key
holes in the back of the system over screw heads on the wall and push
down.
Affixing the Storage System to other surfaces:
Tools required: Alcohol Swab, Lint-Free Cloth, Double-Sided Tape (provided)
1. Locate the desired location for the storage system.
2. Using an alcohol swab, clean all surface mounting areas thoroughly
and then dry with a lint-free cloth.
3. Peel away the backing from one side of the two pieces of double-sided
tape and attach the two pieces of double-sided tape over each of the
key holes on the back of the KleenSpec Illumination Storage System.
See Figure 4
4. Peel away the backing for the double-sided tape and firmly press the
KleenSpec Illumination Storage System to the cleaned surfaces. See
Figure 5.For best adhesion results, do not use the storage system for
24 hours.
Using the Storage System
1. Slide the card of replacement lamps (REF 08800 lamps purchased
separately) inside the storage system from the top. See figure on
reverse.
2. Plug the KleenSpec Illuminator into the outlet. If necessary, wrap the
excess transformer cord between the wall and the storage system.
Place the Vaginal Speculum Illuminator into the front opening of the
storage system.
To clean the KleenSpec Illumination Storage System, wipe it with 70%
Alcohol, CaviWipes, or 10% Bleach Solution.
NOTE: VERIFY LAMP IS TURNED OFF BEFORE PLACING IT INTO THE STORAGE SYSTEM.
Material No. 1200002
1/8” / 3 mm
Figure 1
Figure 2
4”
/
1
0cm
Figure 3
Figure 4
Figure 5
Page view 0
1 2

Summary of Contents

Page 1 - 1/8” / 3 mm

KleenSpec® IlluminationStorage SystemModel # 78820 Mounting InstructionsChoose the mounting method best suited to your mounting surface type:KleenSpec

Page 2 - Manufactured for Welch Allyn

Limited WarrantyInstrumentation purchased new from Welch Allyn, Inc. (Welch Allyn) is warranted to be free from original defects in material and workm

Comments to this Manuals

No comments