OEM Implementation Manual
Welch Allyn
®
SureTemp
®
Plus
Module
71332-0000B
Page view 0
1 2 3 4 5 6 ... 84 85

Summary of Contents

Page 1 - SureTemp

OEM Implementation ManualWelch Allyn® SureTemp® Plus Module 71332-0000B

Page 2

Introduction SureTemp Plus Module OEM Implementation10 Confidential Welch Allyn OEM Technologies 2 - Functional Description Introduction The SureT

Page 3 - Contents

SureTemp Plus Module OEM Implementation Functional DescriptionWelch Allyn OEM Technologies Confidential 11 Module Operation The SureTemp Plus modul

Page 4

Probe Well and Switch SureTemp Plus Module OEM Implementation12 Confidential Welch Allyn OEM Technologies The integrated well design also eliminat

Page 5

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 13 3 - OEM Implementation Introduction The host

Page 6

Mechanical Considerations SureTemp Plus Module OEM Implementation14 Confidential Welch Allyn OEM Technologies Figure 1. Probe Cover Box Receptacl

Page 7 - 1 - Product Overview

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 15 Host Connector Interface The module interfac

Page 8 - Safety and Warnings

Serial Communications Interface SureTemp Plus Module OEM Implementation16 Confidential Welch Allyn OEM Technologies Table 2 depicts typical power

Page 9 - Measuring Principle

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 17 Figure 3. State Diagram: PredictProbe pulle

Page 10 - 2 - Functional Description

Asynchronous Operation SureTemp Plus Module OEM Implementation18 Confidential Welch Allyn OEM Technologies Figure 4. Thermometry ModuleProbe Conn

Page 11 - Probe Well

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 19 Time-out All time-outs return the module to

Page 12 - Probe Well Switch

Confidential Copyright © 2004 by Welch Allyn OEM Technologies. Welch Allyn ® , SureTemp ® and SureTemp ® Plus are registered trademarks of Welc

Page 13 - 3 - OEM Implementation

Guidelines SureTemp Plus Module OEM Implementation20 Confidential Welch Allyn OEM Technologies Guidelines Welch Allyn strongly recommends that you

Page 14

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 21Adult Axillary ModeFigure 6. Acceptable Ways

Page 15 - Levels follow Vcc and ground

Guidelines SureTemp Plus Module OEM Implementation22 Confidential Welch Allyn OEM TechnologiesFigure 8. Acceptable Ways to Display the Rectal Mode

Page 16 - Asynchronous Operation

SureTemp Plus Module OEM Implementation OEM ImplementationWelch Allyn OEM Technologies Confidential 23Ready Audible SignalProvide an audible indicat

Page 17

Guidelines SureTemp Plus Module OEM Implementation24 Confidential Welch Allyn OEM Technologies4 - SpecificationsThe Welch Allyn SureTemp Plus module

Page 18 - Figure 4. Thermometry Module

SureTemp Plus Module OEM Implementation SpecificationsWelch Allyn OEM Technologies Confidential 25EnvironmentalAmbient Operating RangeTemperature 50

Page 19 - Time-out

Introduction SureTemp Plus Module OEM Implementation26 Confidential Welch Allyn OEM Technologies5 - Verification TestingIntroductionThis section pro

Page 20 - Guidelines

SureTemp Plus Module OEM Implementation RegulatoryWelch Allyn OEM Technologies Confidential 276 - RegulatoryIntroductionThe Welch Allyn SureTemp Plu

Page 21 - Rectal Mode

OEM Responsibility SureTemp Plus Module OEM Implementation28 Confidential Welch Allyn OEM TechnologiesTable 5. Regulatory Test Descriptions and St

Page 22 - Monitor Mode

SureTemp Plus Module OEM Implementation Part NumbersWelch Allyn OEM Technologies Confidential 297 - Part NumbersComponents from Welch AllynTable 6.

Page 23 - Completion Audible Signal

Welch Allyn OEM Technologies Confidential 3 Contents 1 - Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - 4 - Specifications

Introduction SureTemp Plus Module OEM Implementation30 Confidential Welch Allyn OEM Technologies8 - Communications ProtocolIntroductionThe SureTemp

Page 25

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 31Two possible approaches to changing the d

Page 26 - 5 - Verification Testing

Packet Structure SureTemp Plus Module OEM Implementation32 Confidential Welch Allyn OEM TechnologiesCommand BlockResponse BlockType CodesData Types

Page 27 - 6 - Regulatory

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 33Simple Data TypesData Type C Language Bas

Page 28

Packet Structure SureTemp Plus Module OEM Implementation34 Confidential Welch Allyn OEM TechnologiesComplex Data Types (Structures)TEMP_STATUSType

Page 29 - 7 - Part Numbers

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 35TEMP (33 data bytes)Type Description Valu

Page 30 - 8 - Communications Protocol

Packet Structure SureTemp Plus Module OEM Implementation36 Confidential Welch Allyn OEM TechnologiesTEMP (19 data bytes)Type Description Values/Uni

Page 31 - Packet Structure

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 37Checksum CalculationThe checksum is a sin

Page 32 - Data Types

Commands and Responses SureTemp Plus Module OEM Implementation38 Confidential Welch Allyn OEM TechnologiesCommands and Responses(2900) Send Serial

Page 33 - Simple Data Types

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 39(2936) Send Module Software VersionCauses

Page 34 - TEMP_STATUS

Contents SureTemp Plus Module OEM Implementation4 Confidential Welch Allyn OEM Technologies 4 - Specifications . . . . . . . . . . . . . . . . . .

Page 35 - TEMP (33 data bytes)

Commands and Responses SureTemp Plus Module OEM Implementation40 Confidential Welch Allyn OEM Technologies(2945) Send Thermometer Probe ModeCauses

Page 36 - TEMP (19 data bytes)

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 41(2A06) Save Data to EEPROMCauses the modu

Page 37 - Checksum Calculation

Commands and Responses SureTemp Plus Module OEM Implementation42 Confidential Welch Allyn OEM Technologies(2A12) Set Temperature MethodCauses the m

Page 38 - Commands and Responses

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 43(2A35) Set Thermometer Probe ModeCauses t

Page 39 - Response Data

Commands and Responses SureTemp Plus Module OEM Implementation44 Confidential Welch Allyn OEM Technologies(2A37) Set Default Thermometer Probe Mode

Page 40

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 45(3101) Send Digital Input StatusCauses th

Page 41 - (2A06) Save Data to EEPROM

Commands and Responses SureTemp Plus Module OEM Implementation46 Confidential Welch Allyn OEM Technologies(3109) Erase Event LogCauses the module t

Page 42 - (2A12) Set Temperature Method

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 47(3604) Set Temperature ProbeCauses the un

Page 43

Commands and Responses SureTemp Plus Module OEM Implementation48 Confidential Welch Allyn OEM Technologies(9413) Send Mode Pause For Clinical Devic

Page 44 - (3000) Restart Module

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 49(9416) Send 690 Event LogCauses the modul

Page 45

SureTemp Plus Module OEM Implementation ContentsWelch Allyn OEM Technologies Confidential 5 (2A37) Set Default Thermometer Probe Mode . . . . . . .

Page 46 - (3503) Lock Thermometer Probe

Commands and Responses SureTemp Plus Module OEM Implementation50 Confidential Welch Allyn OEM Technologies(941C) Send Temperature Record Causes the

Page 47 - (3604) Set Temperature Probe

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 51(9433) Set Mode Pause For Clinical Device

Page 48

Commands and Responses SureTemp Plus Module OEM Implementation52 Confidential Welch Allyn OEM Technologies(9434) Set Asynchronous Messages EnabledC

Page 49 - (9416) Send 690 Event Log

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 53(9435) Set Default Thermometer ModeCauses

Page 50

Commands and Responses SureTemp Plus Module OEM Implementation54 Confidential Welch Allyn OEM Technologies(943A) Set Programmable Ambient BiasCause

Page 51

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 55Command and Response Strings: ExamplesThi

Page 52

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation56 Confidential Welch Allyn OEM TechnologiesThese steps are shown in

Page 53

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 57String Examples(2900) Send Serial Number

Page 54 - Data Records

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation58 Confidential Welch Allyn OEM Technologies(2936) Send Module Softwa

Page 55 - Endianness

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 59(2A12) Set Temperature MethodCauses the u

Page 56

Contents SureTemp Plus Module OEM Implementation6 Confidential Welch Allyn OEM Technologies Personal Computer Requirements. . . . . . . . . . . .

Page 57 - String Examples

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation60 Confidential Welch Allyn OEM Technologies(3503) Lock Thermometer P

Page 58

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 61(9401) Send Thermometer Status No Clear C

Page 59

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation62 Confidential Welch Allyn OEM Technologies05: Spare- 004: Spare- 00

Page 60

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 63(941C) Send Temperature Record - 19 Data

Page 61

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation64 Confidential Welch Allyn OEM Technologies(941C) Send Temperature R

Page 62

SureTemp Plus Module OEM Implementation Communications ProtocolWelch Allyn OEM Technologies Confidential 65(9434) Enable Asynchronous MessagesCauses

Page 63

Command and Response Strings: Examples SureTemp Plus Module OEM Implementation66 Confidential Welch Allyn OEM Technologies(943A) Set Programmable A

Page 64

SureTemp Plus Module OEM Implementation Quick StartWelch Allyn OEM Technologies Confidential 679 - Quick StartIntroductionThis provides a quick-star

Page 65

Typical Start-up Sequence SureTemp Plus Module OEM Implementation68 Confidential Welch Allyn OEM Technologies7. The module sends unsolicited <94

Page 66

SureTemp Plus Module OEM Implementation Programmable Ambient BiasWelch Allyn OEM Technologies Confidential 6910 - Programmable Ambient BiasIntroduct

Page 67 - 9 - Quick Start

SureTemp Plus Module OEM Implementation Product OverviewWelch Allyn OEM Technologies Confidential 7 1 - Product Overview Introduction Temperature i

Page 68

Calculating the Bias SureTemp Plus Module OEM Implementation70 Confidential Welch Allyn OEM Technologies4. After the two temperatures are collected

Page 69 - Introduction

SureTemp Plus Module OEM Implementation Error Codes and RecoveryWelch Allyn OEM Technologies Confidential 7111 - Error Codes and RecoveryTable 8 defi

Page 70 - Saving Ambient Bias

Saving Ambient Bias SureTemp Plus Module OEM Implementation72 Confidential Welch Allyn OEM Technologies45 Probe, Module, PatientMeasurement below a

Page 71 - 11 - Error Codes and Recovery

SureTemp Plus Module OEM Implementation Error Codes and RecoveryWelch Allyn OEM Technologies Confidential 7370 Probe Problem reading the probe'

Page 72

Saving Ambient Bias SureTemp Plus Module OEM Implementation74 Confidential Welch Allyn OEM Technologies

Page 73

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 75Appendix A - Developer’s KitIntroductionThe SureT

Page 74

Setup SureTemp Plus Module OEM Implementation76 Confidential Welch Allyn OEM TechnologiesSetupPersonal Computer RequirementsThe SureTemp Plus PC so

Page 75 - Appendix A - Developer’s Kit

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 77Figure 11. SureTemp Plus Evaluation Platform

Page 76 - Hardware Installation

SureTemp Plus PC Display SureTemp Plus Module OEM Implementation78 Confidential Welch Allyn OEM TechnologiesSureTemp Plus PC DisplayFigure 12. Han

Page 77

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 79Normal Mode1. The program defaults to Normal (pre

Page 78 - SureTemp Plus PC Display

Safety and Warnings SureTemp Plus Module OEM Implementation8 Confidential Welch Allyn OEM Technologies Safety and Warnings To obtain accurate and

Page 79 - Normal Mode

SureTemp Plus PC Display SureTemp Plus Module OEM Implementation80 Confidential Welch Allyn OEM TechnologiesExtended ViewsExtended View options can

Page 80 - Extended Views

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 81The Temperature Profile Graph can be printed by cl

Page 81 - Communications Log

SureTemp Plus PC Display SureTemp Plus Module OEM Implementation82 Confidential Welch Allyn OEM TechnologiesMiscellaneous FunctionsThis section des

Page 82 - Miscellaneous Functions

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 83Comms Log WindowFigure 17. Comms Log WindowFull

Page 83 - Full Display

SureTemp Plus Module OEM Implementation Developer’s KitWelch Allyn OEM Technologies Confidential 84Predict LogFigure 19. Predict Log Display

Page 84

SureTemp Plus Module OEM Implementation CleaningWelch Allyn OEM Technologies Confidential 85Appendix B - CleaningCleaning the ProbeWipe the probe an

Page 85 - Appendix B - Cleaning

SureTemp Plus Module OEM Implementation Product OverviewWelch Allyn OEM Technologies Confidential 9 Measuring Principle The Welch Allyn proprietary