Standard Cable Pinouts
Laser Output Only (Laser Compatible Bar Image)
10 Pin Modular Plug
connects to the scanner handle
1 Turn on good read or LED beeper
2 Trigger signal to decoder
3 Laser enable
4 Supply ground
5
6 Digital bar code data output
7 5 volt power connection
8
9 Start of scan
10
Start of scan
Digital bar code data output
Turn on good read LED or beeper
N/C
Trigger signal to decoder
9 Pin Type D Female
connects to your terminal
Laser enable
Supply ground
Cord shield
5 Volt power connection
1
2
3
4
5
6
7
8
9
Pins4and 9 are populated depending on power supplyvoltage option.
Some decoders mayhave +12V on pins4or9. Connect to +5VDC ONLY!
Conventional laser data format is provided at the modular connector in the scanner handle. The
interface cable is terminated with a 10 pin modular plug, and a 9 pin Type D (squeeze to release)
connector that is compatible with all Hand Held Products terminals.