Telepen, continued
Message Length
The message length selection is used to set the valid reading length of the bar
code. If the data length of the scanned bar code doesnt match the valid reading
length, the scanner will issue an error beep. You may wish to set the same value
for minimum and maximum length to force the scanner to read fixed length bar
code data. This helps reduce the chances of a misread.
EXAMPLE: Decode only those bar codes with a count of 9-20 characters.
Min. length = 09 Max. length = 20
EXAMPLE: Decode only those bar codes with a count of 15 characters.
Min. length = 15 Max. length = 15
For a value other than the minimum and maximum message length defaults,
scan the bar codes below, then scan the 2-digit value and Save bar codes on the
Programming Chart inside the back cover. Minimum and Maximum
lengths = 1-60.
Note: Ifyoumakeanerror while scanning thedigits (before scanning Save),
scan Discard on the back cover,scan the Minimum or Maximum bar
code,scan the correct digits, and Save again.
Minimum (Default =1)
Maximum (Default =60)