Battery Conservation Mode
The scanner offers three low power modes: 1) No timeout, 2) Dont check base
network before timeout, and 3) Check base network before timeout.
The lowest standby current is achieved with No timeout selected. When the
scanner is idle, the standby current is about 15 mA. Radio contact is maintained
and workgroup configuration settings are maintained. No timeout is the default
setting and is recommended if the scanner is active for most of the workday and
the charge pack is removed when the scanner is not in use. Alternately, to fully
discharge the battery, leave the charge pack attached and power off the base. If
the scanner goes out of range or the base unit is powered off, the scanner goes
into an active search mode for the base. In this mode, the average current draw
is about 50 mA.
If Dont check base network before timeout is selected and the scanner is idle,
the standby current is about 20 mA for one timeout period. The standby current
then drops to about 10 mA until the trigger is pulled. The timeout period is
selectable in increments of 15 minutes up to one hour. On the next trigger-pull,
the scanner begins the reassociation process to restore the radio link and the
workgroup configuration settings. This setting is recommended if the scanner is
left inactive for long periods of time during the workday or if the charge pack is
left attached when the scanner is not in use.
The Check base network before timeout mode is identical to the previous mode
except that when the timeout period expires, the scanner tests whether it is still
in radio contact with the base. If radio contact has been lost, the standby current
drops to about 10 mA; otherwise, it remains at 20 mA and the timeout clock
begins another timeout period. This setting may be recommended if the charge
pack is left attached and the base is powered off at the end of each working day.