Programming the Scanner
Preamble characters may include Code ID and the ASCII characters
(00–7F). These characters will be transmitted in the order in which the
selections are programmed.
Both preamble and postamble menuing must always start with a clean
slate. Therefore, to clear all preambles, it is necessary only to complete the
programming sequence SCAN ENTER, SCAN I, SCAN EXIT.
If the Code ID is selected as a preamble, the wand will transmit a single
lower case ASCII character to identify which symbology was decoded.
For example, Code 3 of 9 is identified by a lower case “b,” while Code 128
is identified by a lower case “j.”
The code identifier for each bar code symbology is listed below and
appears immediately following the symbology name on the Symbology
Selection Menu Page.
SYMBOLOGY CODE ID
CODABAR a
Code 3 of 9 b
UPC c
EAN d
Interleaved 2 of 5 e
Code 2 of 5 f
MSI g
Code 1 h
Code 93 i
Code 128 j
Postamble
Postamble(s) are programmable data identifiers which follow the bar code
messages. Up to five (5) postambles which include the ASCII characters
(00–7F) can be programmed. Postamble characters will be transmitted in
the order in which they are selected. Since postamble selections also begin
with a clean slate, the programming sequence SCAN ENTER, SCAN II,
SCAN EXIT will remove existing postambles from the decoder
configuration.