4–11
Programming the Scanner
SHIFT LOCK
When you are operating in SHIFT LOCK mode, the 2380 should also be
programmed for SHIFT LOCK mode (i.e., SHIFT LOCK enabled).
Intercharacter Delay
Intercharacter Delay is the time delay between data characters output by
the 2380. The delay is in (X5) milliseconds and can be set to any value
between 00 and 99 (X5ms).
Interfunction Delay
Interfunction delay is the time delay between “function key” characters
output by the 2380. The delay is in (X5) milliseconds, and any value
between 00 and 99 (X5ms) may be selected.
Intermessage Delay
Intermessage delay is the time delay between messages output by the 2380.
The delay is in (X5) milliseconds and can be set to any value between 00
and 99 (X5ms).
Beeper
This programming selection permits control of the beeper located in the
scanner as a means of indicating scanning activity to the operator. The
BEEPER option described below is listed on the Programming Menu.
Beep (On Reset)
When “Beep” (On Reset) is enabled (YES), the beeper in the scanner will
“beep once” to indicate that the wand is operational. This single “beep” can
be interpreted as a SCANNER READY message from the wand.
Beep (On Good Read)§
When “Beep” (On Good Read) is enabled (YES), the beeper in the scanner
will “beep once” following a scan only if the bar code data has been
accepted by the host. If the beeper does not sound, the scan should be
repeated.