4–17
Programming the Scanner
FUNCTION SELECTION VARIABLE
Set Check Digit D
To Required Yes
Set Check Digit E
To Transmit Yes
Set Full ASCII F
To Enabled Yes
Set Code 128 VIII
To Enabled Yes
Set Minimum Length A
To 6 0
6
Set Maximum Length B
To 12 1
2
Disable CODABAR(1) I No
Disable I 2 of 5(1) III No
Disable Code 11(1) V No
Disable Code 93(1) VI No
Disable MSI (Plessey)(1) VIII No
Leave Menu Page EXIT
(1) – To maximize reading efficiency and security, all unused codes should
be disabled. Because all industrial codes default to an enabled (YES)
state, it is necessary to disable all codes except Code 39 and Code
128.