Programming the Scanner
CASE 1 – Function Codes “Enabled”
With the Function Code Transmit selection enabled, the SCANTEAM 2380
outputs 1234HT5678 to the terminal as:
F10 1 2 3 4 “TAB ”5 6 7 8 ENTER
preamble postamble
Notice that Keyboard Function Code, HT, has been translated and sent as
the TAB key.
CASE 2 – Function Codes “Disabled” (Commercial Application):
When the Function Code Transmit selection is disabled, the SCANTEAM
2380 outputs 1234HT5678 to the terminal as:
F10 1 2 3 4 5 6 7 8 ENTER
Notice now that HT has been stripped from the data string. Note also, that
Keyboard Function Codes contained within the Preamble and Postamble
(F10 and ENTER) are not affected by the Function Code Transmit
selection (XII) and so they are translated and sent.
Keyboard Function Records
Keyboard Function Records are special incoming data records which
originate from the Scanner.
Keyboard Function Records are translated by the SCANTEAM 2380 and
sent to the terminal as keyboard function keys. The function which is
emulated depends upon both the Keyboard Function Record and the
terminal selection. The key functions emulated by each Keyboard
Function Record are listed according to terminal type in Appendix C.
Keyboard Function Records differ from Keyboard Function Codes in the
following ways:
(1) Keyboard Function Records cannot be disabled by menu
programming.
(2) Keyboard Function Records cannot be embedded within other
Scanner data; they are stand alone records, and if embedded, will be
treated as normal data.